BJJRL - EMIT DIGOXIN SERUM PRETREATMENT RGNT,6H419
- MSDS: BJJRL
- Manufacturer: SYVA (A SYNTEX COMPANY)
- Product Name: EMIT DIGOXIN SERUM PRETREATMENT RGNT,6H419
- National Stock Number: 6550-00N010890
Product Identification
Product ID:EMIT DIGOXIN SERUM PRETREATMENT RGNT,6H419
MSDS Date:04/24/1986
FSC:6550
NIIN:00N010890
MSDS Number: BJJRL
Responsible Party
Emergency Phone: 408-446-9966
Info Phone: 408-446-9966
Cage: HO623
Contractor
Telephone: 408-239-2000
Cage: 61815
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 98.0%
OSHA PEL N/K
ACGIH TLV: N/K
SODIUM HYDROXIDE (SARA III)
CAS: 1310-73-2
RTECS: WB4900000
Fraction By Weight: 2.0%
OSHA PEL 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE EYE DAMAGE.INGESTION WILL
CAUSE POSSIBLE DAMAGE TO MOUTH & ESOPHAGUS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES:MAY CAUSE DAMAGE.SKIN:PROLONGED CONTACT
MAY CAUSE IRRITATION.INGESTION:WILL CAUSE IRRITATION & POSSIBLE
DAMAGE TO MOUTH & ESOPHAGUS.INHALATION:WILL CAUSE IRRITATION TO
NOSE,LUNGS,RESPIRATORY TRAC T,MUCOUS MEMBRANES.
Medical Cond Aggravated by Exposure:N/K
First Aid
First Aid:EYES:FLUSH IMMEDIATELY WITH WATER FOR AT LEAST 15
MINUTES.CONTACT SUPERVISOR & PHYSICIAN.SKIN:FLUSH IMMEDIATELY WITH
WATER FOR 15 MINUTES.IF IRRITATION PERSISTS,CONTACT SUPERVISOR &
PHYSICIAN.INGESTIO N:DO NOT INDUCE VOMITING.GIVE LARGE QUANTITIES
OF MILK OR WATER & CONTACT SUPERVISOR & PHYSICIAN.INHALATION:REMOVE
TO FRESH AIR.CONTACT SUPERVISOR & PHYSICIAN.
Fire Fighting
Flash Point:NOT COMBUSTIBLE
Lower Limits:NONE
Upper Limits:NONE
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:HAZARDOUS DECOMPOSITION PRODUCTS:NONE
Accidental Release
Spill Release Procedures:AVOID SKIN CONTACT.NEUTRALIZE W/ CITRIC ACID
OR DILUTE HCL SOLUTION.ABSORB W/ DRY ABSORBING MATLS.WEAR PERSONAL
PROTECTION.LARGE SPILL:WEAR APPROPRIATE PROTECTIVE CLOTHING (EYE
PROTECTION,NEOPRENE GLO VES,LAB COAT/COVERALLS,RESPIRATOR).
Neutralizing Agent:CITRIC ACID OR DILUTE HCL SOLUTION
Handling
Handling and Storage Precautions:NONE
Other Precautions:CAUTION,IRRITANT.MAY CAUSE EYE DAMAGE.MAY CAUSE
IRRITATION TO SKIN & MUCOUS MEMBRANES.AVOID INHALATION & CONTACT W/
EYES,SKIN & CLOTHING.CONTAINS STRONG ALKALI.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW TLV .
Protective Gloves:NEOPRENE
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:IN CASE OF LARGE SPILL-APPROP PROT EQUP:EYE
PROTECTION,NEOPRENE GLOVES,LAB COAT/COVERALLS,RESPIRATOR.
Work Hygienic Practices:N/K
Supplemental Safety and Health
BP:N/K (WATER:100C,212F).ROUTES OF ENTRY:INHALATION/SKIN/INGESTION .
Chemical Properties
Boiling Pt:B.P. Text:SUPP DATA
Melt/Freeze Pt:M.P/F.P Text:SOLUTION
Decomp Temp:Decomp Text:N/K
Solubility in Water:SOLUTION
Appearance and Odor:CLEAR AQUEOUS SOLUTION.
Stability
Stability Indicator/Materials to Avoid:YES
ACIDS & METALS (AL,SN,ZN).NAOH MAY REACT WITH CO*2 IN AIR TO FORM
NA*2CO*3.
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:NONE
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE & LOCAL REGULATIONS .NEUTRALIZED SOLUTIONS CAN BE
RELEASED TO SEWER.ASSAY SOLUTIONS MAY NEED TO BE HANDLED AS
INFECTIOUS WASTE AS HUMAN FLUIDS A RE BEING ASSAYED.HANDLE/DISPOSE
ACCORDING TO REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.